{"id":14174,"date":"2023-02-16T18:22:50","date_gmt":"2023-02-16T17:22:50","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=14174"},"modified":"2024-02-27T12:19:32","modified_gmt":"2024-02-27T11:19:32","slug":"liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/","title":{"rendered":"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14174\" class=\"elementor elementor-14174\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-935fbeb elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"935fbeb\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-34dbcce\" data-id=\"34dbcce\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-861e376 elementor-widget elementor-widget-text-editor\" data-id=\"861e376\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Liver<\/strong> plays a fundamental role in <strong>metabolic activities<\/strong> such as the regulation of glucose levels in the blood, production of plasma proteins, drug metabolism, production of bile [1][2] and presents a complex structure from a morphological and functional point of view [3].<\/p><p>Since its importance, it has been widely investigated in the past decades to understand the mechanisms of drugs metabolism and toxicity (DILI &ndash; Drug-Induced Liver Injury) as well as hepatic diseases such as hepatitis, cirrhosis, fibrosis and cancers [4][5][6].<\/p><h2>Short overview of the liver sinusoid structure<\/h2><p>The hepatic portal vein (from the gut) and the hepatic artery take the blood to liver, where it is mixed in capillaries called sinusoids and collected in the hepatic central vein, where it is carried back to heart.<\/p><p>The liver is composed by repeating units, the lobules, with hexagonal shape, that consist of hepatocytes (HCs) arranged in cord structures around the sinusoids, separated by a perisinusoidal space, the space of Disse.<\/p><p>The <strong>hepatocytes<\/strong> are the parenchymal liver cells, mainly involved in proteins and bile synthesis and in the liver metabolism while the main non-parenchymal (NPC) cells are the liver sinusoidal endothelial cells (LSECs), the Kupffer cells (macrophages) and the stellate cells. Hepatocytes receive the nutrients from the sinusoidal cells through exchanges across the space of Disse [2] [7][8].<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-79e6e1a elementor-widget elementor-widget-image\" data-id=\"79e6e1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"239\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1-300x239.webp\" class=\"attachment-medium size-medium wp-image-14176\" alt=\"drawing of a liver on chip\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1-300x239.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1.webp 769w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1: Scheme of the liver sinusoid. The sinusoid, where the blood flows, is separated from the parenchyma, composed of hepatocytes, by a membrane of sinusoidal endothelial cells and by the space of Disse. The 4 main types of cells are endothelial, Kupffer and stellate cells (non-parenchymal) and the hepatocytes. Figure from Tsutsui et al [9].<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f2493e elementor-widget elementor-widget-text-editor\" data-id=\"2f2493e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Engineered liver in-vitro models<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a1490a elementor-widget elementor-widget-image\" data-id=\"3a1490a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"286\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Capture-1-1024x458.webp\" class=\"attachment-large size-large wp-image-14177\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Capture-1-1024x458.webp 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Capture-1-300x134.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Capture-1-768x343.webp 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Capture-1.webp 1237w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2: Graphical representation of the common approaches for liver in vitro models. The approaches can be classified as non-perfusion systems (MPCCs, 3D spheroids) and perfusion systems (Liver-on-chip) while the high-throughput cell microarrays are usually used for drugs screening and development [2][10]. <\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c4974d6 elementor-widget elementor-widget-text-editor\" data-id=\"c4974d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>A liver-on-a-chip model: The artifical liver sinusoid<\/h3><p>We have decided to describe here the artificial liver sinusoid developed by Lee et al., who designed a microfluidic platform able to recreate a physiological microenvironment (mass transport conditions) for the seeding of primary hepatocytes [11].<\/p><h3>Details on chip design<\/h3><p>The microfluidic platform was composed of a channel for the flow of nutrients and drugs and a cell compartment for the seeding of tightly packed hepatocytes.<\/p><p>In fact, it has been demonstrated that high densities of primary cells allow the formation of cell-cell interactions with augmented viability and metabolic activity.<\/p><p>A permeable<strong> endothelial-like barrier<\/strong> with a sinusoidal shape composed of a set of parallel microchannels was included into the chip design in order to (i) prevent high shear stresses that can be dangerous for the HCs and (ii) pack the HCs in the cell area.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15df077 elementor-widget elementor-widget-image\" data-id=\"15df077\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"223\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip-1.webp\" class=\"attachment-large size-large wp-image-14181\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip-1.webp 850w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip-1-300x104.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip-1-768x267.webp 768w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3: The artificial liver sinusoid designed by Lee et al. The flow channel and the cells chamber are 50 &micro;m wide and 30 &micro;m high. The two areas mimic respectively the blood vessel and the liver parenchyma and are separated by a barrier composed of parallel microchannels (2 x 1 &micro;m &ndash; width x height) that play the role of the liver endothelial cells (LSECs). The barrier allows at the same time to tightly pack hepatocytes in the cell area (right image) while ensuring low shear stresses.  (Scale bar 50 &micro;m). Figure from Moraes et al. [8].<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b0e1ed elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"9b0e1ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGAN-ON-CHIP: THE FUTURE OF RESEARCH?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-organ-on-a-chip\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGAN-ON-CHIP: THE FUTURE OF RESEARCH?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our cutting-edge solutions for advanced research and development!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-405bf0d elementor-widget elementor-widget-text-editor\" data-id=\"405bf0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>How to make a liver on a chip?<\/h2><h3>Chip microfabrication<\/h3><p>SU-8 (a <span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/products\/hare-sq-negative-epoxy-photoresist-for-soft-lithography?variant=41035182014628\">negative photoresist<\/a><\/strong><\/span>) was patterned through <span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/blogs\/reviews\/the-most-used-microfabrication-techniques-in-microfluidics\">photolithography<\/a> <\/strong><\/span>on a silicon wafer in two steps: a 1 &micro;m thick SU-8 layer was spin-coated to create the channels of the endothelial-like barrier, then a 30 &micro;m SU-8 was used to create the channels for the flow and the cells seeding.<br>Successively, <b>poly-dimethyl siloxane<\/b> (<span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/products\/sylgard-184-pdms-elsatomer\">PDMS<\/a><\/strong><\/span>) chips were replicated from the SU-8 mold and bonded to a glass slide.<\/p><h3>Designing the chip parameters to mimic the liver microcirculation<\/h3><p>The chip was designed to ensure a nutrient volumetric flow of 100 pL\/s (for about 250 hepatocytes loaded in the cell area), typical of liver microcirculation. To do so, the channels width, height and length were set at (50 x 30 x 1200) &micro;m and (2 x 1 x 30) &micro;m for the flow channel and the permeable barrier respectively.<\/p><p>Using a barrier channels cross-section of 2 x 1 &micro;m, a low convective flow, so a high total fluidic resistance (1000 times higher than in the fluid channel) were ensured, thus enabling diffusive transport. In this way, HCs were exposed to low <span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/blogs\/reviews\/shear-stress-in-microfluidic-devices\">shear stresses<\/a><\/strong><\/span> and could receive nutrients through diffusion across the barrier.<\/p><h3>Designing the chip parameters to control the loading of tightly packed hepatocytes<\/h3><p>The design of the endothelial-like barrier also allowed the loading of a <strong>high density of HCs<\/strong> without damaging them or the barrier itself.<\/p><p>The narrow cross-section of the channels was verified to reduce the cells membrane deformation at the interface.<\/p><p>Thus, a positive flow directed the cells towards the bottom of the cell area without clogging, that resulted in a high cells packaging. Furthermore, an increasing resistance produced by the cells determined a decrease of the loading rate at the end of the seeding process.<\/p><h2>Microfluidic chip for primary cells culture: Results and conclusion<\/h2><p>Both rat and human primary hepatocytes were loaded within the cell area and the cell viability was assessed up to 7 days.<br>The microfluidic platform was continuously perfused with culture medium. Results shown that both the cell lines maintained their viability after 7 days with no need of collagen coating (necessary in static culture systems).<\/p><p>Moreover, the high density of cells ensured a high metabolic activity due to cell-cell contacts.<\/p><p><strong>The review shows how microfluidic platforms can be engineered to closely mimic specific functions of a tissue or an organ. In this work, a microfluidic device composed of a flow channel, a cell area and a permeable endothelial-like barrier was designed to resemble the liver microcirculation conditions, improving the hepatocytes viability and the cell-cell interactions.<\/strong><\/p><p>&nbsp;<span style=\"color: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem; letter-spacing: -0.01rem;\">Review written by Alessandra Dellaquila.<\/span><\/p><h3><strong>References<\/strong><\/h3><p>[1] Y. B. Kang <em>et al.<\/em>, &ldquo;Liver sinusoid on a chip: Long&#8208;term layered co&#8208;culture of primary rat hepatocytes and endothelial cells in microfluidic platforms,&rdquo; <em>Biotechnol. Bioeng.<\/em>, vol. 112, no. 12, pp. 2571&ndash;2582, 2015.<\/p><p>[2] C. H. Beckwitt <em>et al.<\/em>, &ldquo;liver &lsquo;organ on a chip,&rsquo;&rdquo; <em>Exp. Cell Res.<\/em>, 2017.<\/p><p>[3] Y. Du <em>et al.<\/em>, &ldquo;Mimicking liver sinusoidal structures and functions using a 3D-configured microfluidic chip,&rdquo; <em>Lab Chip<\/em>, vol. 17, no. 5, pp. 782&ndash;794, 2017.<\/p><p>[4] L. A. Vernetti <em>et al.<\/em>, &ldquo;A human liver microphysiology platform for investigating physiology, drug safety, and disease models,&rdquo; <em>Exp. Biol. Med.<\/em>, vol. 241, no. 1, pp. 101&ndash;114, 2016.<\/p><p>[5] V. Natarajan, E. N. Harris, and S. Kidambi, &ldquo;SECs (sinusoidal endothelial cells), liver microenvironment, and fibrosis,&rdquo; <em>Biomed Res. Int.<\/em>, vol. 2017, 2017.<\/p><p>[6] S. S. Bale <em>et al.<\/em>, &ldquo;In vitro platforms for evaluating liver toxicity,&rdquo; <em>Exp. Biol. Med.<\/em>, vol. 239, no. 9, pp. 1180&ndash;1191, 2014.<\/p><p>[7] A. J. Strain and J. M. Neuberger, &ldquo;A bioartificial liver&ndash;state of the art,&rdquo; <em>Science (80-. ).<\/em>, vol. 295, no. 5557, pp. 1005&ndash;1009, 2002.<\/p><p>[8] C. Moraes, G. Mehta, S. C. Lesher-Perez, and S. Takayama, <em>Organs-on-a-Chip: A Focus on Compartmentalized Microdevices<\/em>, vol. 40. 2011.<\/p><p>[9] H. Tsutsui and S. Nishiguchi, <em>Importance of Kupffer Cells in the Development of Acute Liver Injuries in Mice<\/em>, vol. 15. 2014.<\/p><p>[10] G. H. Underhill and S. R. Khetani, &ldquo;Bioengineered Liver Models for Drug Testing and Cell Differentiation Studies,&rdquo; <em>Cell. Mol. Gastroenterol. Hepatol.<\/em>, vol. 5, no. 3, pp. 426&ndash;439, 2018.<\/p><p>[11] P. J. Lee, P. J. Hung, and L. P. Lee, &ldquo;An artificial liver sinusoid with a microfluidic endothelial&#8208;like barrier for primary hepatocyte culture,&rdquo; <em>Biotechnol. <\/em><em>Bioeng.<\/em>, vol. 97, no. 5, pp. 1340&ndash;1346, 2007.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Liver plays a fundamental role in metabolic activities such as the regulation of glucose levels in the blood, production of plasma proteins, drug metabolism, production of bile [1][2] and presents a complex structure from a morphological and functional point of&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14176,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,21],"tags":[],"class_list":["post-14174","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids<\/title>\n<meta name=\"description\" content=\"The liver plays a fundamental role in metabolic activities, discover in this review how to reproduce it using microfluidics!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids\" \/>\n<meta property=\"og:description\" content=\"The liver plays a fundamental role in metabolic activities, discover in this review how to reproduce it using microfluidics!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-16T17:22:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:19:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"769\" \/>\n\t<meta property=\"og:image:height\" content=\"613\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids\",\"datePublished\":\"2023-02-16T17:22:50+00:00\",\"dateModified\":\"2024-02-27T11:19:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/\"},\"wordCount\":1217,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/liver_on_chip_review-1.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/\",\"name\":\"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/liver_on_chip_review-1.webp\",\"datePublished\":\"2023-02-16T17:22:50+00:00\",\"dateModified\":\"2024-02-27T11:19:32+00:00\",\"description\":\"The liver plays a fundamental role in metabolic activities, discover in this review how to reproduce it using microfluidics!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/liver_on_chip_review-1.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/liver_on_chip_review-1.webp\",\"width\":769,\"height\":613,\"caption\":\"drawing of a liver on chip\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids","description":"The liver plays a fundamental role in metabolic activities, discover in this review how to reproduce it using microfluidics!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/","og_locale":"en_US","og_type":"article","og_title":"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids","og_description":"The liver plays a fundamental role in metabolic activities, discover in this review how to reproduce it using microfluidics!","og_url":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-16T17:22:50+00:00","article_modified_time":"2024-02-27T11:19:32+00:00","og_image":[{"width":769,"height":613,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids","datePublished":"2023-02-16T17:22:50+00:00","dateModified":"2024-02-27T11:19:32+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/"},"wordCount":1217,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1.webp","articleSection":["Cell culture &amp; organ-on-chip","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/","url":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/","name":"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1.webp","datePublished":"2023-02-16T17:22:50+00:00","dateModified":"2024-02-27T11:19:32+00:00","description":"The liver plays a fundamental role in metabolic activities, discover in this review how to reproduce it using microfluidics!","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1.webp","width":769,"height":613,"caption":"drawing of a liver on chip"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/liver-on-a-chip-beyond-the-chip-design-to-mimic-natural-sinusoids\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Liver-on-a-Chip: Beyond the chip design to mimic natural sinusoids"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/liver_on_chip_review-1.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14174","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=14174"}],"version-history":[{"count":24,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14174\/revisions"}],"predecessor-version":[{"id":18486,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14174\/revisions\/18486"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14176"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=14174"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=14174"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=14174"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}