{"id":14296,"date":"2023-02-22T11:23:19","date_gmt":"2023-02-22T10:23:19","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=14296"},"modified":"2024-02-27T12:12:58","modified_gmt":"2024-02-27T11:12:58","slug":"step-emulsification-for-high-throughput-droplet-generation-a-review","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/","title":{"rendered":"Step emulsification for high-throughput droplet generation: a review"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14296\" class=\"elementor elementor-14296\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5195888 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5195888\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6ac86e1\" data-id=\"6ac86e1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0f534f3 elementor-widget elementor-widget-text-editor\" data-id=\"0f534f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The step emulsification is a variant of the droplet generation technique called co-flow. This new technique is based on the instability of a two-phase liquid wire triggered by an abrupt change in the flow confinement (Figure 1). It is more directly inspired by <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/microchannel-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">microchannel<\/a> emulsification since it uses microfabricated channel networks that allow remarkably tight geometric control of the droplet size.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a511b2 elementor-widget elementor-widget-image\" data-id=\"5a511b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"160\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1-300x160.webp\" class=\"attachment-medium size-medium wp-image-14298\" alt=\"Schematic illustration of a step emulsification channel\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1-300x160.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1.webp 660w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1: Schematic illustration of a step emulsification channel. The drop breakup occurs at the step between the nozzle and the continuous phase channel. Ofner et al. 2016 Macromol. Chem. Phys.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8294f01 elementor-widget elementor-widget-text-editor\" data-id=\"8294f01\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Mechanism of step emulsification<\/h2><p>The step emulsification technique is used to generate droplets with diameters ranging from nanometers to hundreds of micrometers. To carry out this process, the necessary equipment consists of a dispersed phase channel, a reservoir of the continuous phase, and a nozzle, with a height that is significantly different from the reservoir.<\/p><p>To characterize this technique, several geometric models have been established. Among these models, it is the quasi-static mechanism that has been retained by most researchers to understand how the drops are generated. According to Dangla et al. 2013 J Phys D Appl Phys, this model is conditioned by three hypotheses:<\/p><ol><li>the dispersed phase is not able to wet the channel walls for droplet formation,<\/li><li>gravitational effect is negligible,<\/li><li>the system evolves in a quasi-static manner.<\/li><\/ol><p>To successfully generate droplets by step emulsification, the continuous phase containing the surfactant must be injected first in order to fill the reservoir. The dispersed immiscible phase is then injected into the channel. Thus, as the thread of the dispersed phase passes through the step, a bulb emerges downstream of the step. As the dispersed phase is continuously injected, the average curvature of the blub decreases, while its size increases (Figure 2).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03cc5a1 elementor-widget elementor-widget-image\" data-id=\"03cc5a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"260\" height=\"221\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Cross-section_views_of_the_nozzle_in_two_lateral_direction-1.webp\" class=\"attachment-medium size-medium wp-image-14302\" alt=\"\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2: Cross-sectional views of the nozzle in two lateral directions. I.The dispersed phase is injected into the nozzle. II. The radius of bulb reaches the critical value and begins to form the necking region. III. The diameter of the neck decreases to the nozzle height after necking. IV. The droplet detaches from the dispersed phase into the continuous phase. Shi et al. 2020. R. Soc. Chem.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-348c523 elementor-widget elementor-widget-global elementor-global-18298 elementor-widget-pix-promo-box\" data-id=\"348c523\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"WANT TO SIMPLIFY MICROFLUIDIC DROPLET GENERATION?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/pressure-controller\/products\/ob1-microfluidic-droplet-pack\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">WANT TO SIMPLIFY MICROFLUIDIC DROPLET GENERATION?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Unlock the potential of our user-friendly systems for effortless droplet generation<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08c8378 elementor-widget elementor-widget-text-editor\" data-id=\"08c8378\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Types of step emulsification designs<\/h2><p>The grooved-type <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/microchannel-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">microchannel<\/a> emulsification step is governed by interfacial tension for droplet formation when using pressure or flow rate. Classically, the grooved <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/microchannel-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">microchannel<\/a> includes a dispersed phase channel, a nozzle, a terrace and a continuous phase reservoir (Figure 3a). This kind of device can be manufactured on a silicon wafer by <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/photolithography-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">photolithography<\/a> and orientation-dependent etching.<\/p><p>A second example is the use of a straight <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/microchannel-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">microchannel<\/a> for stepwise emulsification, the structure of which includes elongated straight holes for the formation of droplets (Figure 3b). The droplet diameter is linearly related to the depth of the straight hole, which is roughly a multiple of 4. For the manufacture of this device, deep reactive ion etching (DRIE) on a silicon wafer can be used.<\/p><p>Another step emulsification structure allowing the generation of droplets at high flow rates is the Edge Droplet Generation Device (EDGE). This time it will no longer be a straight hole but a wide, shallow plateau as a nozzle, in which parallel droplets are generated simultaneously from a single nozzle (Figure 3c). To make this device, a silicon wafer is etched using the deep reactive ion etching (DRIE) technique and then bonded with a glass plate.<\/p><p>So far, only rectangular nozzles have been used in the above-mentioned devices. However, triangular nozzles have demonstrated much better performance. The triangular nozzle then acts as a terrace for the backflow of the continuous phase with the stretched cross-section (Figure 3d). In this way, the triangular nozzle provides an independent local area for the formation of droplets in order to avoid unwanted interference of the dispersed and continuous phases.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7a3925 elementor-widget elementor-widget-image\" data-id=\"b7a3925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"148\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_of_microfluidic_step_emulsification_devices-1.webp\" class=\"attachment-medium_large size-medium_large wp-image-14303\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_of_microfluidic_step_emulsification_devices-1.webp 704w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_of_microfluidic_step_emulsification_devices-1-300x69.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63c206b elementor-widget elementor-widget-text-editor\" data-id=\"63c206b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In step emulsification, it is important to note that the size of the monodisperse droplets is related to the geometrical characterizations of the <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/microchannel-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">microchannel<\/a>, which means that the droplet diameter is difficult to adjust once the <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/microchannel-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">microchannel<\/a> is designed.<\/p><p>Although limited in droplet size by geometry, step emulsification is a robust tool especially when combined with detection, identification and information technologies, which will improve the measurement of bioinformation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b68076 elementor-widget elementor-widget-global elementor-global-18301 elementor-widget-pix-promo-box\" data-id=\"5b68076\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"LOOKING TO SCALE UP YOUR DROPLET PRODUCTION?\"\/><div class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">LOOKING TO SCALE UP YOUR DROPLET PRODUCTION?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our scalable solutions designed to meet the demands of high-throughput droplet generation with ease<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The step emulsification is a variant of the droplet generation technique called co-flow. This new technique is based on the instability of a two-phase liquid wire triggered by an abrupt change in the flow confinement (Figure 1). It is more&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14298,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[23,21],"tags":[],"class_list":["post-14296","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-droplet-generation","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Step emulsification for high-throughput droplet generation: a review<\/title>\n<meta name=\"description\" content=\"Step emulsification is a variant of droplet generation. This technique allows a high throughput of small droplets. Find out how!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Step emulsification for high-throughput droplet generation: a review\" \/>\n<meta property=\"og:description\" content=\"Step emulsification is a variant of droplet generation. This technique allows a high throughput of small droplets. Find out how!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-22T10:23:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:12:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"660\" \/>\n\t<meta property=\"og:image:height\" content=\"351\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Step emulsification for high-throughput droplet generation: a review\",\"datePublished\":\"2023-02-22T10:23:19+00:00\",\"dateModified\":\"2024-02-27T11:12:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/\"},\"wordCount\":745,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"articleSection\":[\"Droplet generation\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/\",\"name\":\"Step emulsification for high-throughput droplet generation: a review\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"datePublished\":\"2023-02-22T10:23:19+00:00\",\"dateModified\":\"2024-02-27T11:12:58+00:00\",\"description\":\"Step emulsification is a variant of droplet generation. This technique allows a high throughput of small droplets. Find out how!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"width\":660,\"height\":351,\"caption\":\"Schematic illustration of a step emulsification channel\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/step-emulsification-for-high-throughput-droplet-generation-a-review\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Step emulsification for high-throughput droplet generation: a review\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Step emulsification for high-throughput droplet generation: a review","description":"Step emulsification is a variant of droplet generation. This technique allows a high throughput of small droplets. Find out how!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/","og_locale":"en_US","og_type":"article","og_title":"Step emulsification for high-throughput droplet generation: a review","og_description":"Step emulsification is a variant of droplet generation. This technique allows a high throughput of small droplets. Find out how!","og_url":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T10:23:19+00:00","article_modified_time":"2024-02-27T11:12:58+00:00","og_image":[{"width":660,"height":351,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Step emulsification for high-throughput droplet generation: a review","datePublished":"2023-02-22T10:23:19+00:00","dateModified":"2024-02-27T11:12:58+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/"},"wordCount":745,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1.webp","articleSection":["Droplet generation","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/","url":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/","name":"Step emulsification for high-throughput droplet generation: a review","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1.webp","datePublished":"2023-02-22T10:23:19+00:00","dateModified":"2024-02-27T11:12:58+00:00","description":"Step emulsification is a variant of droplet generation. This technique allows a high throughput of small droplets. Find out how!","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1.webp","width":660,"height":351,"caption":"Schematic illustration of a step emulsification channel"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/step-emulsification-for-high-throughput-droplet-generation-a-review\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Step emulsification for high-throughput droplet generation: a review"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_a_step_emulsification_channel-1.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=14296"}],"version-history":[{"count":11,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14296\/revisions"}],"predecessor-version":[{"id":18460,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14296\/revisions\/18460"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14298"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=14296"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=14296"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=14296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}