{"id":14349,"date":"2023-02-22T12:39:57","date_gmt":"2023-02-22T11:39:57","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=14349"},"modified":"2024-02-27T12:10:49","modified_gmt":"2024-02-27T11:10:49","slug":"cell-trapping-in-microfluidics-a-review","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/","title":{"rendered":"Cell trapping in microfluidics: a review"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14349\" class=\"elementor elementor-14349\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9263981 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9263981\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-090988e\" data-id=\"090988e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d20a1c9 elementor-widget elementor-widget-text-editor\" data-id=\"d20a1c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Microfluidic-based hydrodynamic trap facilitates trapping using the sole action of fluid flow and provides a viable alternative to existing confinement and manipulation techniques based on electric, optical, magnetic or acoustic force fields for example. In this review, we describe various methods and techniques utilized in microfluidic spheroid and single-cell trapping.<\/p><h2>Single-cell trapping processes<\/h2><p>One of the most robust methods to analyze populations of single cells in relatively high throughput are microwell arrays.<\/p><p>However, a recurring problem is that microwell cultures are static. This limits their ability to actively manipulate the trapped cells, for example to change the medium or to control the exposure of the cells to mitogenic stimuli. On the other hand, microfluidic valves, optical tweezers, dielectrophoresis (DEP) and acoustic waves, which can be easily integrated with microfluidic devices, allow more powerful approaches to trapping and manipulating individual cells.<\/p><p>In this review, we have chosen to rely on the study of Koben et al. in 2018, in which they were able to evaluate the trapping force according to different chip designs. In their study, Koben et al. present a microfluidic device capable of trapping a single cell via a network of traps whose main channel length can be 1, 2 or 4 mm with respectively 64 traps in parallel and 3 to 10 traps in series. Each chip then has two inlets, one for medium infusion and one for cell loading.<\/p><p>In practice, the chip was first primed with complete cell culture medium at a flow rate of 25 ml\/min and the cells were injected through the spare inlet. After closing the cell inlet with a stopper, the chip was placed on an inverted microscope, infused at a flow rate of 20 nl\/min and the ratio between successful and unsuccessful traps was quantified. In order to analyse a sufficiently large number of trapping events for statistical analysis, the already trapped cells were removed from the traps by reversing the direction of flow for about 1.5 to 2 s and restarting the infusion.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f49c52f elementor-widget elementor-widget-image\" data-id=\"f49c52f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"334\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_the_single_cell_trap_with_two_inserts_describing_the_fluid_flow_in_the_trap.-1-1024x535.webp\" class=\"attachment-large size-large wp-image-14352\" alt=\"Schematic illustration of the single cell trap with two inserts describing the fluid flow in the trap.\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_the_single_cell_trap_with_two_inserts_describing_the_fluid_flow_in_the_trap.-1-1024x535.webp 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_the_single_cell_trap_with_two_inserts_describing_the_fluid_flow_in_the_trap.-1-300x157.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_the_single_cell_trap_with_two_inserts_describing_the_fluid_flow_in_the_trap.-1-768x401.webp 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_illustration_of_the_single_cell_trap_with_two_inserts_describing_the_fluid_flow_in_the_trap.-1.webp 1090w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1: (A) Schematic illustration of the single cell trap with two inserts describing the fluid flow in the trap. The trap consists of a long looped main channel, a cavity for a single cell and a 3-mm high gap. Extracted from Kobel et al. 2010 Lab Chip (B) Schematic of the microfluidic device, which contains a whole blood sample inlet and a buffer inlet, respectively. After the whole blood sample flowed to the bifurcation region (orange zone), plasma and RBCs were extracted to plasma zone and RBC zone, respectively. WBCs flowed to the main channel and were trapped in the WBC zone. Extracted from Kuan et al. 2018 Scientific Reports.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-863371f elementor-widget elementor-widget-text-editor\" data-id=\"863371f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>An other smart device was designed to allow the loading of a whole blood sample (fig. 1 B). It consists of a whole blood inlet, a buffer inlet and a bifurcation region, which leads to three blood component collection areas: a plasma area, a red blood cell (RBC) area and a white blood cell (WBC) area. The separation mechanism for red and white blood cells is based on the bifurcation law and the cross-flow (saline) method. The bifurcation region contains six bead-filled side channels, four narrowed side channels and one main channel for plasma extraction, red blood cell extraction and white blood cell trapping, respectively. In order to achieve a uniform flow profile in the bifurcation region, all side channels have been inclined at 60 degrees to the main channel.<\/p><p>Typically, RBCs have a diameter of 6.2-8.2 &mu;m and a thickness of 2-2.5 &mu;m and WBCs have a diameter of 7-18 &mu;m. Due to the density of 10-&mu;m balls in the side channel, the effective pore size is 1.55 &mu;m. Therefore, all blood cells would pass through and only plasma can circulate in the plasma area and be collected.<\/p><h2>Spheroid trapping processes<\/h2><h3>U-Shaped microstructures<\/h3><p>The U-shaped microstructures operate either temporarily, by pneumatic actuation, or permanently inside the device. Many of these U-shaped microstructures are usually integrated. The diameter of the spheroids depends on the size of the microstructure, while the relative position of the microstructures is essential for effective cell trapping.<\/p><p>In addition, it is possible to modulate the time of spheroid formation using the flow rate. However, high flow rates cause the cells to escape from the trap. On the other hand, in order to keep the spheroids inside the microstructures, the flow must be maintained, thus maintaining the necessary stagnation pressure.<\/p><p>&nbsp;<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24fe981 elementor-widget elementor-widget-image\" data-id=\"24fe981\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"288\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1-300x288.webp\" class=\"attachment-medium size-medium wp-image-14359\" alt=\"This figure depicts the droplets four days after being trapped in the microsieve structures for spheroid formation.\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1-300x288.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1-768x737.webp 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp 779w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2: This figure depicts the droplets four days after being trapped in the microsieve structures for spheroid formation. The gaps between the microsieves enable proper diffusional nutrient and gas exchange. Extracted from Yu et al. 2010 Lab Chip.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-546fa8c elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"546fa8c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGAN-ON-CHIP: THE FUTURE OF RESEARCH?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-organ-on-a-chip\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGAN-ON-CHIP: THE FUTURE OF RESEARCH?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our cutting-edge solutions for advanced research and development!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e64d742 elementor-widget elementor-widget-text-editor\" data-id=\"e64d742\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Microwell-based Microfluidic spheroid formation chips (&micro;SFC)<\/h3><p>In general, a microwell-based &micro;SFC needs a specified number of microwells and a <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/microchannel-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">microchannel<\/a> network to deliver the culture medium. Microchannels should be designed in a way that can prevent undesirable spheroid escape from the microwells. Experimentally, it has been indicated that increasing the channel width or decreasing its height can limit spheroid escape.<\/p><p>In order to equalize flow rates across several microchannels, flow resistance must be the same through all of them. Therefore, if channels have the same width and height, their lengths must also be equal to satisfy this requirement. Sinuous channels, often used in concentration gradient generators (CGGs) as mixing channels, are appropriate to adjust channel length precisely within a smallarea of the chip. Such channels can thus be applied for flow control purposes rather than including valves within microfluidic chips. Desired flow rates must also take into account the number of cells existing in the culture environment and their corresponding requirements for oxygen, nutrients and other factors.<\/p><p>There are many devices that can be used to trap organised cells called spheroids or organoids. In the figure 3 we present some of these devices.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70f3a6b elementor-widget elementor-widget-image\" data-id=\"70f3a6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"355\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Differents_microfluidic_device_for_spheroid_trapping-1-1024x568.webp\" class=\"attachment-large size-large wp-image-14363\" alt=\"Schematic of a multiple design for cell-trapping in microfluidic\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Differents_microfluidic_device_for_spheroid_trapping-1-1024x568.webp 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Differents_microfluidic_device_for_spheroid_trapping-1-300x166.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Differents_microfluidic_device_for_spheroid_trapping-1-768x426.webp 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Differents_microfluidic_device_for_spheroid_trapping-1-1536x852.webp 1536w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Differents_microfluidic_device_for_spheroid_trapping-1.webp 1867w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3: (A) Single-emulsion (Gel\/O) device using microwells to anchor cell-dispensed hydrogel droplets. Extracted from Sart et al. 2017 Nature Com. (B) Single-emulsion (Gel\/O) droplet generation chip for spheroid generation having sinusoidal anchoring array. Sabhachandani et al. 2016 Lab Chip. (C) Single-emulsion (CS\/O) spheroid formation device containing sinusoidal anchoring arrays. McMillan et al. 2016, Analyst.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Microfluidic-based hydrodynamic trap facilitates trapping using the sole action of fluid flow and provides a viable alternative to existing confinement and manipulation techniques based on electric, optical, magnetic or acoustic force fields for example. In this review, we describe various&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14359,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[27,21],"tags":[],"class_list":["post-14349","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Cell trapping in microfluidics: a review - Darwin Microfluidics<\/title>\n<meta name=\"description\" content=\"In this review, we describe various methods and techniques utilized in microfluidic spheroid and single-cell trapping.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cell trapping in microfluidics: a review - Darwin Microfluidics\" \/>\n<meta property=\"og:description\" content=\"In this review, we describe various methods and techniques utilized in microfluidic spheroid and single-cell trapping.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-22T11:39:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:10:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"779\" \/>\n\t<meta property=\"og:image:height\" content=\"748\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Cell trapping in microfluidics: a review\",\"datePublished\":\"2023-02-22T11:39:57+00:00\",\"dateModified\":\"2024-02-27T11:10:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/\"},\"wordCount\":1029,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/\",\"name\":\"Cell trapping in microfluidics: a review - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp\",\"datePublished\":\"2023-02-22T11:39:57+00:00\",\"dateModified\":\"2024-02-27T11:10:49+00:00\",\"description\":\"In this review, we describe various methods and techniques utilized in microfluidic spheroid and single-cell trapping.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp\",\"width\":779,\"height\":748,\"caption\":\"This figure depicts the droplets four days after being trapped in the microsieve structures for spheroid formation.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/cell-trapping-in-microfluidics-a-review\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cell trapping in microfluidics: a review\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cell trapping in microfluidics: a review - Darwin Microfluidics","description":"In this review, we describe various methods and techniques utilized in microfluidic spheroid and single-cell trapping.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/","og_locale":"en_US","og_type":"article","og_title":"Cell trapping in microfluidics: a review - Darwin Microfluidics","og_description":"In this review, we describe various methods and techniques utilized in microfluidic spheroid and single-cell trapping.","og_url":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T11:39:57+00:00","article_modified_time":"2024-02-27T11:10:49+00:00","og_image":[{"width":779,"height":748,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Cell trapping in microfluidics: a review","datePublished":"2023-02-22T11:39:57+00:00","dateModified":"2024-02-27T11:10:49+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/"},"wordCount":1029,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp","articleSection":["Cell culture &amp; organ-on-chip","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/","url":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/","name":"Cell trapping in microfluidics: a review - Darwin Microfluidics","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp","datePublished":"2023-02-22T11:39:57+00:00","dateModified":"2024-02-27T11:10:49+00:00","description":"In this review, we describe various methods and techniques utilized in microfluidic spheroid and single-cell trapping.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp","width":779,"height":748,"caption":"This figure depicts the droplets four days after being trapped in the microsieve structures for spheroid formation."},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/cell-trapping-in-microfluidics-a-review\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Cell trapping in microfluidics: a review"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/This_figure_depicts_the_droplets_four_days_after_being_trapped_in_the_microsieve_structures_for_spheroid_formation.-1.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14349","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=14349"}],"version-history":[{"count":21,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14349\/revisions"}],"predecessor-version":[{"id":18446,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14349\/revisions\/18446"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14359"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=14349"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=14349"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=14349"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}