{"id":14425,"date":"2023-02-22T15:36:50","date_gmt":"2023-02-22T14:36:50","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=14425"},"modified":"2026-11-19T15:12:59","modified_gmt":"2026-11-19T14:12:59","slug":"comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/","title":{"rendered":"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14425\" class=\"elementor elementor-14425\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e56ba51 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e56ba51\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c723abd\" data-id=\"c723abd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6a7072d elementor-widget elementor-widget-text-editor\" data-id=\"6a7072d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>By definition, a liposome consists of a lipid bilayer that encapsulates an aqueous phase. Liposomes are increasingly used to deliver drugs in a targeted and size-controlled manner. This is where microfluidics comes in. Indeed, the science of fluid handling systems is used for the extremely precise control of very small volumes, which is very appropriate in the generation of micro- and nanosized liposomes. In this application note, we will compare literature to results obtained with two designs of microfluidic chips for generating nanoliposomes: the herringbone micromixer and the hydrodynamic flow focusing. These microfluidic chips have received a hydrophilic coating. To generate nanoliposomes, we chose to use PLGA (Poly(Lactic-Co-Glycolic Acid) solubilized in acetonitrile. The aqueous phase consists of water and surfactant (1% PVA).<\/p><h2>Herringbone mixer<\/h2><p>The herringbone micromixer chip is an all-in-one solution that allows the mixing of two fluids in a microfluidic channel in a simple and efficient way. This tool is suitable for many applications such as immunoassays or PCR product mixes, but also for the generation of nanoliposomes. This type of chip can be made in various materials, including PDMS, glass and thermoplastics (PC, COC, COP, etc.).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d90fb3 elementor-widget elementor-widget-image\" data-id=\"4d90fb3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"392\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_1_One_half-cycle_of_the_SHM-1.webp\" class=\"attachment-large size-large wp-image-14427\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_1_One_half-cycle_of_the_SHM-1.webp 716w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_1_One_half-cycle_of_the_SHM-1-300x184.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1: One half-cycle of a SHM (staggered herringbone mixer), with a channel cross-section of w &times; h and 10 herringbones with points offset 1\/3 of the way across the channel. Each half-cycle alternates with a complementary unit, in which the herringbones are offset to the opposite side of the midline, to complete a full mixing cycle. Extracted from Williams et al. 2008, Lab Chip.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0889a44 elementor-widget elementor-widget-text-editor\" data-id=\"0889a44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>With this method, it is possible to generate nanoliposomes of a size between 100 and 200 nm, according to Roces et al. 2020, Pharmaceutics.<\/p><p>In practice, we generated nanoliposomes using a herringbone micromixer chip made of polycarbonate (microfluidic ChipShop, 10000019). The results indicate that we generated nanoliposomes with an average size of 247 nm &plusmn; 78.8 nm. The measurements were made by dynamic light scattering using the Zetasizer Nano ZS on 11 samples with flow rate ratios ranging from 1 to 15.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-80e83ce elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"80e83ce\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-f358f06\" data-id=\"f358f06\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1d74492 elementor-widget elementor-widget-image\" data-id=\"1d74492\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"366\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_2_SHM_results-1.webp\" class=\"attachment-large size-large wp-image-14432\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_2_SHM_results-1.webp 964w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_2_SHM_results-1-300x172.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_2_SHM_results-1-768x440.webp 768w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-0747e43\" data-id=\"0747e43\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-144cf4e elementor-widget elementor-widget-image\" data-id=\"144cf4e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"393\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_2_SHM_results_2-1.webp\" class=\"attachment-large size-large wp-image-14433\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_2_SHM_results_2-1.webp 740w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_2_SHM_results_2-1-300x184.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-518c75d elementor-widget elementor-widget-text-editor\" data-id=\"518c75d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\">Figure 2: Measurement of the nanoliposomes diameters generated by a straggered herringbone mixer device (microfluidic ChipShop, 10000019). &quot;FRR&quot; stands for flow rate ratio: it corresponds to the ratio between the flow of the continuous phase and the flow of the dispersed phase. Measurements performed by Christelle Ang&eacute;ly on a Zetasizer Nano ZS (Malvern Panalytical) of the biochemistry and biophysics platform of the Institute of Psychiatry and Neuroscience of Paris.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3747083 elementor-widget elementor-widget-global elementor-global-18286 elementor-widget-pix-promo-box\" data-id=\"3747083\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Imaging_1920x600_DARWIN_MICROFLUIDICS-2.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"READY TO REVOLUTIONIZE DRUG DELIVERY WITH LIPID NANOPARTICLES?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/products\/lipid-nanoparticle-synthesis-pack\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">READY TO REVOLUTIONIZE DRUG DELIVERY WITH LIPID NANOPARTICLES?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Optimize your research processes and achieve faster results with our innovative solutions!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23e6052 elementor-widget elementor-widget-text-editor\" data-id=\"23e6052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Hydrodynamic flow focusing<\/h2><p>The hydrodynamic flow focusing microfluidic device allows for precise mixing of the reagents with short mixing times under <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/laminar-flow-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">laminar flow<\/a> conditions, which enables the generation of, for example, monodisperse <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> of adjustable size.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642eb2f elementor-widget elementor-widget-image\" data-id=\"642eb2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"386\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_3_Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device-1.webp\" class=\"attachment-large size-large wp-image-14434\" alt=\"Illustration of nucleation and growth mechanism of nanoprecipitation along the focus mixing channel in a hydrodynamic flow focusing device\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_3_Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device-1.webp 680w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG_3_Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device-1-300x181.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3: Illustration of nucleation and growth mechanism of nanoprecipitation along the focus mixing channel in a hydrodynamic flow focusing device. Extracted from Lababidi et al. 2019, Beilstein J. Nanotechnol.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7852d86 elementor-widget elementor-widget-text-editor\" data-id=\"7852d86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Using this flow-focusing technique, it is possible to generate nanoliposomes with a size &gt;150 nm and usually around 200 nm. However, depending on the composition of the nanoliposomes, their size can change considerably as in the work of Karnik et al. presented in 2008. Indeed, the team is able to produce <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> of 31 nm in diameter (&plusmn; 1 nm) in a highly monodisperse manner.<\/p><p>In our case, we were able to generate nanoliposomes with an average size of 250.9 nm &plusmn; 66.8 nm using a flow-focusing chip made of polycarbonate (microfluidic ChipShop, 10000004). The measurements were made by dynamic light scattering using the Zetasizer Nano ZS on 11 samples with flow rate ratios ranging from 1 to 15.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-1eb467d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1eb467d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-007ae19\" data-id=\"007ae19\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-998191a elementor-widget elementor-widget-image\" data-id=\"998191a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"420\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG4_FF_results_1-1.webp\" class=\"attachment-large size-large wp-image-14441\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG4_FF_results_1-1.webp 781w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG4_FF_results_1-1-300x197.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG4_FF_results_1-1-768x504.webp 768w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\"><\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-da03b0b\" data-id=\"da03b0b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8169bc1 elementor-widget elementor-widget-image\" data-id=\"8169bc1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"400\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG4_FF_results_2-1.webp\" class=\"attachment-large size-large wp-image-14442\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG4_FF_results_2-1.webp 914w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG4_FF_results_2-1-300x187.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FIG4_FF_results_2-1-768x480.webp 768w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3641ae elementor-widget elementor-widget-text-editor\" data-id=\"f3641ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\">Figure 4: Measurement of the nanoliposomes diameters generated by a flow focusing device (microfluidic ChipShop, 10000004). &quot;FRR&quot; stands for flow rate ratio: it corresponds to the ratio between the flow of the continuous phase and the flow of the dispersed phase. Measurements performed by Christelle Ang&eacute;ly on a Zetasizer Nano ZS (Malvern Panalytical) of the biochemistry and biophysics platform of the Institute of Psychiatry and Neuroscience of Paris.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a35f59 elementor-widget elementor-widget-text-editor\" data-id=\"2a35f59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In conclusion, the two methods presented here were able to generate nanoliposomes of similar size, i.e. about 250 nm in diameter, regardless of the flow rate ratio. The choice of the composition of the nanoliposome, whether it be the choice of lipid, solvent or aqueous phase, should therefore be taken into consideration. In addition, several well-documented techniques are effective in reducing the size of the nanoliposomes generated. For example, it is possible to perform a sonication (1 to 5 min) of the sample to reduce its size by up to 50%. Numerous publications describe filtration and\/or dialysis as very efficient ways to purify nanoliposomes and thus reduce their size (from 50 to 80 nm).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>By definition, a liposome consists of a lipid bilayer that encapsulates an aqueous phase. Liposomes are increasingly used to deliver drugs in a targeted and size-controlled manner. This is where microfluidics comes in. Indeed, the science of fluid handling systems&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14825,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[29,26],"tags":[],"class_list":["post-14425","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-nanoparticles-lnp"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Comparing two microfluidic chip designs for nanoliposomes (LNP) generation<\/title>\n<meta name=\"description\" content=\"In this application note, we will compare literature to results obtained with two designs of microfluidic chips for generating nanoliposomes.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation\" \/>\n<meta property=\"og:description\" content=\"In this application note, we will compare literature to results obtained with two designs of microfluidic chips for generating nanoliposomes.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-22T14:36:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:12:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation\",\"datePublished\":\"2023-02-22T14:36:50+00:00\",\"dateModified\":\"2026-11-19T14:12:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/\"},\"wordCount\":769,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp\",\"articleSection\":[\"Application notes\",\"Nanoparticles &amp; LNP\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/\",\"name\":\"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp\",\"datePublished\":\"2023-02-22T14:36:50+00:00\",\"dateModified\":\"2026-11-19T14:12:59+00:00\",\"description\":\"In this application note, we will compare literature to results obtained with two designs of microfluidic chips for generating nanoliposomes.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp\",\"width\":1000,\"height\":1000,\"caption\":\"Schematic illustation of a ChipShop herringbone Mixer\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation","description":"In this application note, we will compare literature to results obtained with two designs of microfluidic chips for generating nanoliposomes.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/","og_locale":"en_US","og_type":"article","og_title":"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation","og_description":"In this application note, we will compare literature to results obtained with two designs of microfluidic chips for generating nanoliposomes.","og_url":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T14:36:50+00:00","article_modified_time":"2026-11-19T14:12:59+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation","datePublished":"2023-02-22T14:36:50+00:00","dateModified":"2026-11-19T14:12:59+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/"},"wordCount":769,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp","articleSection":["Application notes","Nanoparticles &amp; LNP"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/","url":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/","name":"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp","datePublished":"2023-02-22T14:36:50+00:00","dateModified":"2026-11-19T14:12:59+00:00","description":"In this application note, we will compare literature to results obtained with two designs of microfluidic chips for generating nanoliposomes.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp","width":1000,"height":1000,"caption":"Schematic illustation of a ChipShop herringbone Mixer"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/comparing-two-microfluidic-chip-designs-for-nanoliposomes-lnp-generation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Comparing two microfluidic chip designs for nanoliposomes (LNP) generation"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic-illustation-of-a-ChipShop-herringbone-Mixer-10000019.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14425","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=14425"}],"version-history":[{"count":17,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14425\/revisions"}],"predecessor-version":[{"id":18433,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14425\/revisions\/18433"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14825"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=14425"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=14425"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=14425"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}