{"id":29335,"date":"2024-10-16T11:37:41","date_gmt":"2024-10-16T09:37:41","guid":{"rendered":"https:\/\/blog.darwin-microfluidics.com\/?p=29335"},"modified":"2026-11-19T15:27:06","modified_gmt":"2026-11-19T14:27:06","slug":"components-of-a-bp7-system-mp-advance-evaluation-set","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/","title":{"rendered":"Components of a BP7 System: mp-Advance Evaluation Set"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"29335\" class=\"elementor elementor-29335\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b89e30d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b89e30d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-faf3674\" data-id=\"faf3674\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ed1d175 elementor-widget elementor-widget-text-editor\" data-id=\"ed1d175\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>To conduct basic tests with <a href=\"https:\/\/darwin-microfluidics.com\/bartels-mikrotechnik\/\">Bartels micropumps<\/a>, the <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-basic-evaluation-set\">Bartels basic set<\/a> provides an ideal starting point, including the essential components needed for initial trials. However, for more advanced studies or comprehensive microfluidic applications, the <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-advance-evaluation-set\">Bartels advance evaluation set<\/a> is required. This set extends beyond the capabilities of the basic set by incorporating additional critical components such as a microfluidic chip, pressure and flow sensors, valves, valve drivers, dampers, connectors, and connection cables.<\/p><p>In this blog post, we will explore the essential components of the Bartels advance set and how they enable users to perform precise control and analysis of microfluidic systems, offering deeper insights and functionality beyond basic testing. Each component plays a vital role in enhancing performance, expanding the range of possible experiments with the <a href=\"https:\/\/blog.darwin-microfluidics.com\/bartels-bp7-piezoelectric-micropumps-an-overview\/\">BP7 micropumps<\/a>, and improving system integration.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d312024 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d312024\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7989574\" data-id=\"7989574\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-594207e elementor-widget elementor-widget-heading\" data-id=\"594207e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mp-Basic Evaluation Set<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1263726 elementor-widget elementor-widget-text-editor\" data-id=\"1263726\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Before diving into the advanced components of Bartels&rsquo; micropump systems, it&rsquo;s important to briefly acknowledge the mp-basic evaluation set, which provides the foundation for testing Bartels micropumps. This set includes the <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-multiboard2-evaluation-board\">mp-Multiboard2 controller<\/a>, which operates via a simple software interface and is equipped with four drivers&mdash;<a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-lowdriver-controller\">Lowdriver<\/a>, <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-driver-pump-driver\">Driver<\/a>, <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-highdriver-pump-driver\">Highdriver<\/a>, and <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-highdriver4-pump-driver\">Highdriver4<\/a>&mdash;to support a range of flow rates. The kit also comes with 6 <a href=\"https:\/\/darwin-microfluidics.com\/products\/bartels-bp7-micropump\/\">BP7 Tubing micropumps<\/a>, one meter of 1.3 mm ID <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-t-1-3-mm-tygon-tubing-for-bartels-micropumps\">Tygon LMT-55 tubing<\/a>, and <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-hc-hose-clamps-for-bartels-micropumps?_pos=1&amp;_sid=feab36cd2&amp;_ss=r\">mp-hc hose clamps<\/a> to ensure secure, leak-proof connections between the pump and tubing.<\/p><p>The mp-hc hose clamps, designed for Bartels micropumps, prevent unwanted disconnection or leakages. With an inner diameter of 3 mm and dimensions of 4 x 5.1 mm, these clamps ensure a tight fit, contributing to the system&rsquo;s reliability.<\/p><p>Additionally, the Tygon LMT-55 tubing, with a 1.3 mm inner diameter and 3 mm outer diameter, is transparent, autoclavable, and EtO-sterilizable, making it ideal for various fluid handling applications. For more details on the chemical resistance properties of Tygon LMT-55, be sure to check our comprehensive <a href=\"https:\/\/blog.darwin-microfluidics.com\/tygon-lmt-55-chemical-compatibility-chart\/\">user guide<\/a>.<\/p><p>For a complete breakdown of the basic set and its components, specifically the mp-Multiboard2 and the different micropump drivers, you can refer to our detailed blog post entitled: <a href=\"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-multiboard2-and-comparison-of-the-mp-drivers\/\"><em>Bartels Mp-Multiboard2 and Comparison of the Mp-Drivers.<\/em><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c2f900 elementor-widget elementor-widget-image\" data-id=\"3c2f900\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"418\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-basic-Evaluation-Set-e1729005661843-1024x669.jpg\" class=\"attachment-large size-large wp-image-29018\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-basic-Evaluation-Set-e1729005661843-1024x669.jpg 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-basic-Evaluation-Set-e1729005661843-300x196.jpg 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-basic-Evaluation-Set-e1729005661843-768x502.jpg 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-basic-Evaluation-Set-e1729005661843-1536x1003.jpg 1536w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-basic-Evaluation-Set-e1729005661843.jpg 1920w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Mp-Basic Evaluation Set.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9fb3870 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9fb3870\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e847873\" data-id=\"e847873\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6e68c63 elementor-widget elementor-widget-heading\" data-id=\"6e68c63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mp-Advance Evaluation Set<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc119c7 elementor-widget elementor-widget-text-editor\" data-id=\"bc119c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The mp-advance evaluation set builds on the basic set by adding extra components for more in-depth testing and complex microfluidic setups.<\/p><p>Along with the essentials, the advance set includes key additions like flow and pressure sensors, valves with drivers, a microfluidic chip, and dampers. These components give users more control and flexibility when working with Bartels micropumps, allowing for greater precision in experiments.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7891db6 elementor-widget elementor-widget-heading\" data-id=\"7891db6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Mp-ValvedriverT and Takasago Valves<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-909869b elementor-widget elementor-widget-text-editor\" data-id=\"909869b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-valvedriver-for-bartels-multiboard\">mp-valvedriverT<\/a> is an essential driver for precisely controlling up to two Takasago SMV valves through the Multiboard2, ensuring efficient fluid management. Compact in size, with dimensions of 16 x 40 x 1.6 mm, the mp-valvedriverT operates with a power supply range of 4.5 to 17 VDC and consumes approximately 0.85 mA at 5 V.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-1769054 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1769054\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-fbe36b7\" data-id=\"fbe36b7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5a73918 elementor-widget elementor-widget-text-editor\" data-id=\"5a73918\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/darwin-microfluidics.com\/products\/smv-2-2-nc-active-valve-for-multiboard\">Takasago SMV 2\/2 NC Active Valve<\/a> is a shape-memory alloy valve that integrates with the Multiboard2, using the mp-valvedriverT. This 2\/2 normally closed valve is nearly silent, it has a compact design, with dimensions of 4.0 x 18.4 x 19 mm, and durable materials&mdash;PPS for the valve body and FPM for the membrane. With a power consumption of just 0.3 W and a switching time of 600 ms, it provides efficient fluid control within the system.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-3dea176\" data-id=\"3dea176\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3f9fd6a elementor-widget elementor-widget-image\" data-id=\"3f9fd6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV-300x300.jpg\" class=\"attachment-medium size-medium wp-image-29557\" alt=\"Takasago SMV Valves\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV-300x300.jpg 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV-1024x1024.jpg 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV-150x150.jpg 150w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV-768x768.jpg 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV-400x400.jpg 400w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV-75x75.jpg 75w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV-460x460.jpg 460w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Takasago-SMV.jpg 1280w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-3054b50 elementor-widget elementor-widget-heading\" data-id=\"3054b50\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">SLF3S-0600F Flow Sensor<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-4d239e6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4d239e6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-9e201fc\" data-id=\"9e201fc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-03ca0bb elementor-widget elementor-widget-image\" data-id=\"03ca0bb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor-300x300.jpg\" class=\"attachment-medium size-medium wp-image-29556\" alt=\"SLF3x Liquid Flow Sensor\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor-300x300.jpg 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor-1024x1024.jpg 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor-150x150.jpg 150w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor-768x768.jpg 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor-400x400.jpg 400w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor-75x75.jpg 75w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor-460x460.jpg 460w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/SLF3x-Liquid-Flow-Sensor.jpg 1280w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-be0733f\" data-id=\"be0733f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-cbc07fc elementor-widget elementor-widget-text-editor\" data-id=\"cbc07fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/darwin-microfluidics.com\/products\/slf3x-flow-sensor-for-bartels-pumps\">SLF3S-0600F sensor<\/a>, from <a href=\"https:\/\/darwin-microfluidics.com\/sensirion\/\">Sensirion<\/a>, is integrated with the Bartels Multiboard2, enabling straightforward monitoring of flow rates in microfluidic applications. The sensor supports flow ranges of 0-2000 &micro;L\/min and offers an accuracy and a repeatability, for water, of &plusmn;5% of the measured value (or 0.5 &micro;L\/min, whichever is larger), ensuring reliable measurements even at low flow rates.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-296ed57 elementor-widget elementor-widget-heading\" data-id=\"296ed57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Honeywell ABP Pressure Sensor<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-47aa521 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"47aa521\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-292e8f4\" data-id=\"292e8f4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8bf04fb elementor-widget elementor-widget-text-editor\" data-id=\"8bf04fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/darwin-microfluidics.com\/products\/honeywell-abp-pressure-sensor-for-bartels-pumps\">Honeywell ABP pressure sensor<\/a> is a high-precision, digital sensor designed for use with the Bartels Multiboard2, making it easy to monitor pressure in microfluidic systems. It covers a pressure range from 0 to 1 bar (0 to 15 psi), with a remarkable accuracy of &plusmn;0.25% and a long-term stability, ensuring precise measurements. Compatible with dry gases and non-corrosive fluids, it connects to the Multiboard2 via the provided 4-pin Grove connector cable. Ideal for experiments requiring sensitive pressure control.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-28851e2\" data-id=\"28851e2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f2d49be elementor-widget elementor-widget-image\" data-id=\"f2d49be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor-300x300.jpg\" class=\"attachment-medium size-medium wp-image-29554\" alt=\"Honeywell ABP pressure sensor\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor-300x300.jpg 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor-1024x1024.jpg 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor-150x150.jpg 150w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor-768x768.jpg 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor-400x400.jpg 400w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor-75x75.jpg 75w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor-460x460.jpg 460w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Honeywell-ABP-pressure-sensor.jpg 1280w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-9cc1d8d elementor-widget elementor-widget-heading\" data-id=\"9cc1d8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Mp-Damper<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-1c632dc elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1c632dc\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-2652c06\" data-id=\"2652c06\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-80292ef elementor-widget elementor-widget-image\" data-id=\"80292ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-damper-300x300.jpg\" class=\"attachment-medium size-medium wp-image-29555\" alt=\"mp-damper\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-damper-300x300.jpg 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-damper-150x150.jpg 150w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-damper-768x768.jpg 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-damper-400x400.jpg 400w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-damper-75x75.jpg 75w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-damper-460x460.jpg 460w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-damper.jpg 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-d799fae\" data-id=\"d799fae\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5481f6e elementor-widget elementor-widget-text-editor\" data-id=\"5481f6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/darwin-microfluidics.com\/products\/mp-damper-for-bartels-micropumps\">mp-damper<\/a> is specifically designed to minimize pulsations in the flow generated by the BP7 micropumps, helping to achieve a smoother and more consistent flow rate. This is especially beneficial when paired with a flow sensor, ensuring more precise readings. The damper is compact, with dimensions of 17 x 19 x 5 mm, and is constructed from durable materials including PPSU, FKM, PP, and epoxy-based adhesive, making it a reliable solution for reducing flow pulsatility in demanding applications.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-bcf3f91 elementor-widget elementor-widget-heading\" data-id=\"bcf3f91\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Straight Channel Chip and Mini Luer Connectors<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-008d60d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"008d60d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-a1bf194\" data-id=\"a1bf194\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ffbc4c9 elementor-widget elementor-widget-text-editor\" data-id=\"ffbc4c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The Straight Channel Chip Fluidic 560 from <a href=\"https:\/\/darwin-microfluidics.com\/microfluidic-chipshop\/\">ChipShop<\/a> features a channel orientation that runs lengthwise. It includes four channels with a total channel volume of 50 &micro;L. The channels are 2.775 &micro;m wide, 350 &micro;m deep, and 58.5 mm long. The chip&rsquo;s fluidic interface uses Mini Luer connections, and it is available in different materials such as TOPAS, PC Zeonor, or PS, making it suitable for various microfluidic and chemical compatibility requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-adbe542\" data-id=\"adbe542\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-61be149 elementor-widget elementor-widget-image\" data-id=\"61be149\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"434\" height=\"200\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Fluidic-560.jpg\" class=\"attachment-large size-large wp-image-29576\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Fluidic-560.jpg 434w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/Fluidic-560-300x138.jpg 300w\" sizes=\"(max-width: 434px) 100vw, 434px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-e4a1a67 elementor-widget elementor-widget-text-editor\" data-id=\"e4a1a67\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p><p>With these advanced tools, combined with the easy-to-use mp-Multiboard2, this set offers an advanced look at Bartels&rsquo; product lineup and opens the door to more detailed testing and system optimization.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-40f1c04 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"40f1c04\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b13bd50\" data-id=\"b13bd50\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-33fb778 elementor-widget elementor-widget-heading\" data-id=\"33fb778\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a2a5b5 elementor-widget elementor-widget-text-editor\" data-id=\"2a2a5b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The Bartels advance set offers a comprehensive and versatile solution for those aiming to go beyond basic micropump testing. With added components such as sensors, valves, and more, it allows for precise control, detailed analysis, and smooth integration of complex microfluidic systems. Whether you&rsquo;re working with advanced flow regulation, pressure management, or complex fluidic circuits, the advance set is designed to meet the demands of microfluidic research and applications.<\/p><p>For a more detailed overview of the BP7 micropump, its full range of features, and system components, check out our <a href=\"https:\/\/blog.darwin-microfluidics.com\/bartels-bp7-piezoelectric-micropumps-an-overview\/\">Bartels BP7 overview blog<\/a>. You&rsquo;ll also find other helpful guides in this blog series, including detailed posts on topics like<a href=\"https:\/\/blog.darwin-microfluidics.com\/instructions-for-appropriate-handling-of-the-bp7-micropumps\/\"> instructions and tips for appropriate handling of the BP7 micropumps<\/a> and the <a href=\"https:\/\/blog.darwin-microfluidics.com\/ppsu-polyphenylsulfone-chemical-compatibility-chart\/\">chemical compatibility of PPSU<\/a>, which is the body material of BP7 micropumps.<\/p><p>To stay updated on any changes or upgrades to Bartels products, including datasheets and technical specifications, please refer to the <a href=\"https:\/\/bartels-mikrotechnik.de\/download-area-en\/\" target=\"_blank\" rel=\"noopener\">Bartels Mikrotechnik download area<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d1b840 elementor-widget elementor-widget-text-editor\" data-id=\"1d1b840\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>&#128231; If you have any questions or feedback, please feel free to contact us at <a href=\"https:\/\/darwin-microfluidics.com\/pages\/contact-us\">support@darwin-microfluidics.com.<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab92993 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"ab92993\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Need some help with your microfluidic project?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/contact-us\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Contact our experts!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Need some help with your microfluidic project?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>We can make microfluidics easy for you!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>To conduct basic tests with Bartels micropumps, the Bartels basic set provides an ideal starting point, including the essential components needed for initial trials. However, for more advanced studies or comprehensive microfluidic applications, the Bartels advance evaluation set is required&hellip;.<\/p>\n","protected":false},"author":4,"featured_media":29337,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[24,33],"tags":[],"class_list":["post-29335","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Components of a BP7 System: mp-Advance Evaluation Set<\/title>\n<meta name=\"description\" content=\"Explore the key components of an advanced BP7 microfluidic system, including pumps, sensors, valves, drivers, tubing, and more.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Components of a BP7 System: mp-Advance Evaluation Set\" \/>\n<meta property=\"og:description\" content=\"Explore the key components of an advanced BP7 microfluidic system, including pumps, sensors, valves, drivers, tubing, and more.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2024-10-16T09:37:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:27:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-advanced-Evaluation-Set.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Elia Missi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Components of a BP7 System: mp-Advance Evaluation Set\",\"datePublished\":\"2024-10-16T09:37:41+00:00\",\"dateModified\":\"2026-11-19T14:27:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/\"},\"wordCount\":1058,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/mp-advanced-Evaluation-Set.jpg\",\"articleSection\":[\"Flow control\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/\",\"name\":\"Components of a BP7 System: mp-Advance Evaluation Set\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/mp-advanced-Evaluation-Set.jpg\",\"datePublished\":\"2024-10-16T09:37:41+00:00\",\"dateModified\":\"2026-11-19T14:27:06+00:00\",\"description\":\"Explore the key components of an advanced BP7 microfluidic system, including pumps, sensors, valves, drivers, tubing, and more.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/mp-advanced-Evaluation-Set.jpg\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/mp-advanced-Evaluation-Set.jpg\",\"width\":1920,\"height\":1920,\"caption\":\"mp-advanced Evaluation Set\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/components-of-a-bp7-system-mp-advance-evaluation-set\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Components of a BP7 System: mp-Advance Evaluation Set\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/eliamissi\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Components of a BP7 System: mp-Advance Evaluation Set","description":"Explore the key components of an advanced BP7 microfluidic system, including pumps, sensors, valves, drivers, tubing, and more.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/","og_locale":"en_US","og_type":"article","og_title":"Components of a BP7 System: mp-Advance Evaluation Set","og_description":"Explore the key components of an advanced BP7 microfluidic system, including pumps, sensors, valves, drivers, tubing, and more.","og_url":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-10-16T09:37:41+00:00","article_modified_time":"2026-11-19T14:27:06+00:00","og_image":[{"width":1920,"height":1920,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-advanced-Evaluation-Set.jpg","type":"image\/jpeg"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/"},"author":{"name":"Elia Missi","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/c80a1276036340d7e994346f251af8f5"},"headline":"Components of a BP7 System: mp-Advance Evaluation Set","datePublished":"2024-10-16T09:37:41+00:00","dateModified":"2026-11-19T14:27:06+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/"},"wordCount":1058,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-advanced-Evaluation-Set.jpg","articleSection":["Flow control","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/","url":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/","name":"Components of a BP7 System: mp-Advance Evaluation Set","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-advanced-Evaluation-Set.jpg","datePublished":"2024-10-16T09:37:41+00:00","dateModified":"2026-11-19T14:27:06+00:00","description":"Explore the key components of an advanced BP7 microfluidic system, including pumps, sensors, valves, drivers, tubing, and more.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-advanced-Evaluation-Set.jpg","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-advanced-Evaluation-Set.jpg","width":1920,"height":1920,"caption":"mp-advanced Evaluation Set"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/components-of-a-bp7-system-mp-advance-evaluation-set\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Components of a BP7 System: mp-Advance Evaluation Set"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/eliamissi\/"}]}},"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/10\/mp-advanced-Evaluation-Set.jpg","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/29335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=29335"}],"version-history":[{"count":98,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/29335\/revisions"}],"predecessor-version":[{"id":29606,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/29335\/revisions\/29606"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/29337"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=29335"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=29335"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=29335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}