{"id":34803,"date":"2026-03-31T17:55:05","date_gmt":"2026-03-31T15:55:05","guid":{"rendered":"https:\/\/blog.darwin-microfluidics.com\/?p=34803"},"modified":"2026-11-19T15:35:34","modified_gmt":"2026-11-19T14:35:34","slug":"11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/","title":{"rendered":"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"34803\" class=\"elementor elementor-34803\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5bc23a86 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5bc23a86\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3c27163b\" data-id=\"3c27163b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2fc0296 elementor-widget elementor-widget-theme-post-featured-image elementor-widget-image\" data-id=\"2fc0296\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"theme-post-featured-image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"Harvard Apparatus 11 Pico Plus Elite Syringe PumpdLSP 500 Digital Syringe Pump\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6MzQ4MTEsInVybCI6Imh0dHBzOlwvXC9ibG9nLmRhcndpbi1taWNyb2ZsdWlkaWNzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNlwvMDNcL0hhcnZhcmQtQXBwYXJhdHVzLTExLVBpY28tUGx1cy1FbGl0ZS1TeXJpbmdlLVB1bXBkTFNQLTUwMC1EaWdpdGFsLVN5cmluZ2UtUHVtcC5qcGcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"360\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump-1024x576.jpg\" class=\"attachment-large size-large wp-image-34811\" alt=\"picture of the Harvard Apparatus 11 Pico Plus Elite Syringe Pump VS dLSP 500 Digital Syringe Pump article\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump-1024x576.jpg 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump-300x169.jpg 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump-768x432.jpg 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump-1536x864.jpg 1536w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg 1600w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bca340 elementor-widget elementor-widget-text-editor\" data-id=\"0bca340\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>11 Pico Plus Elite vs dLSP 500 Digital Syringe Pump: Quick Verdict<\/h2><p>The <a href=\"https:\/\/darwin-microfluidics.com\/products\/microfluidic-programmable-11-pico-plus-elite-syringe-pump-harvard-apparatus\"><b>Harvard Apparatus 11 Pico Plus Elite<\/b><\/a> wins for researchers who need the absolute lowest flow rates with proven accuracy from an established manufacturer. Its <strong>0.54 pL\/min minimum flow rate<\/strong>, combined with <strong>&plusmn;0.35% accuracy<\/strong> and <strong>&plusmn;0.05% reproducibility<\/strong>, makes it the clear choice for demanding microfluidic applications where picoliter precision matters.<\/p><p>The <a href=\"https:\/\/darwin-microfluidics.com\/products\/dlsp-500-digital-syringe-pump\"><b>dLSP 500 Digital Syringe Pump<\/b><\/a> takes the lead for labs prioritizing modern connectivity and regulatory compliance. With <strong>Wi-Fi<\/strong>, <strong>Bluetooth<\/strong>, <strong>Ethernet<\/strong>, and <strong>Android app control<\/strong>, plus <strong>21CFR Part 11 compliance<\/strong> in the Pro version, it offers flexibility that the Harvard unit simply cannot match.<\/p><p><strong>Choose the <a href=\"https:\/\/darwin-microfluidics.com\/harvard-apparatus\/\"><b>Harvard Apparatus<\/b><\/a><\/strong> if your work involves ultra-low flow microfluidics, you need to daisy-chain up to <strong>99 pumps<\/strong>, or you value the <strong>2-year warranty<\/strong> from a trusted name. <strong>Choose the dLSP 500<\/strong> if you need wireless control, regulatory documentation for pharmaceutical work, or want a lower entry price point with the standard model.<\/p><h2>Harvard Apparatus 11 Pico Plus Elite Syringe Pump vs dLSP 500 Digital Syringe Pump at a Glance<\/h2><figure><table><thead><tr><th><strong>Feature<\/strong><\/th><th><strong>Harvard Apparatus 11 Pico Plus Elite<\/strong><\/th><th><strong>dLSP 500 Digital Syringe Pump<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>Price Range<\/strong><\/td><td><strong>$4,299.75 &ndash; $4,429.62<\/strong><\/td><td><strong>$3,409.73 &ndash; $5,014.27<\/strong><\/td><\/tr><tr><td><strong>Accuracy<\/strong><\/td><td><strong>&plusmn;0.35%<\/strong><\/td><td><strong>&plusmn;0.5%<\/strong> (Standard) \/ <strong>&plusmn;0.35%<\/strong> (Pro)<\/td><\/tr><tr><td><strong>Min Flow Rate<\/strong><\/td><td><strong>0.54 pL\/min<\/strong><\/td><td><strong>0.3 pL\/min<\/strong> (Pro) \/ <strong>0.7 pL\/min<\/strong> (Standard)<\/td><\/tr><tr><td><strong>Max Flow Rate<\/strong><\/td><td><strong>39.77 mL\/min<\/strong> (single) \/ <strong>11.70 mL\/min<\/strong> (dual)<\/td><td><strong>120 mL\/min<\/strong> (single) \/ <strong>74.7 mL\/min<\/strong> (dual)<\/td><\/tr><tr><td><strong>Display<\/strong><\/td><td><strong>4.3&quot; TFT touchscreen<\/strong><\/td><td><strong>7&quot; IPS HD LCD<\/strong><\/td><\/tr><tr><td><strong>Connectivity<\/strong><\/td><td><strong>USB<\/strong>, <strong>RS-485<\/strong>, <strong>TTL I\/O<\/strong><\/td><td><strong>USB<\/strong>, <strong>RS-485<\/strong>, <strong>Ethernet<\/strong>, <strong>Wi-Fi<\/strong>, <strong>Bluetooth<\/strong><\/td><\/tr><tr><td><strong>Regulatory<\/strong><\/td><td><strong>CE<\/strong>, <strong>ETL<\/strong>, <strong>RoHS<\/strong><\/td><td><strong>21CFR Part 11<\/strong> (Pro version)<\/td><\/tr><tr><td><strong>Warranty<\/strong><\/td><td><strong>2 years<\/strong><\/td><td><strong>Not specified<\/strong><\/td><\/tr><tr><td><strong>Best For<\/strong><\/td><td><strong>Ultra-precision microfluidics<\/strong><\/td><td><strong>Flexible connectivity, pharma compliance<\/strong><\/td><\/tr><\/tbody><\/table><\/figure><p>The comparison reveals <strong>two distinct design philosophies<\/strong>. Harvard Apparatus prioritizes <strong>proven precision<\/strong> and <strong>scalability for multi-pump setups<\/strong>. The <strong>dLSP 500<\/strong> emphasizes modern connectivity options and regulatory compliance features that pharmaceutical labs increasingly require.<\/p><h2>Description of the 11 Pico Plus Elite:<\/h2><p><a href=\"https:\/\/darwin-microfluidics.com\/harvard-apparatus\/\"><b>Harvard Apparatus<\/b><\/a> has manufactured precision laboratory equipment since <strong>1901<\/strong>. The <a href=\"https:\/\/darwin-microfluidics.com\/products\/microfluidic-programmable-11-pico-plus-elite-syringe-pump-harvard-apparatus\"><b>11 Pico Plus Elite<\/b><\/a> represents their flagship microfluidic syringe pump, designed specifically for applications requiring picoliter-level precision.<\/p><p>This programmable infusion\/withdrawal pump delivers flow rates from <strong>0.54 pL\/min<\/strong> to <strong>39.77 mL\/min<\/strong> in single-syringe configuration. The dual-syringe version handles <strong>0.5 &mu;L to 10 mL<\/strong> syringes with flow rates up to <strong>11.70 mL\/min<\/strong>. Both configurations maintain <strong>&plusmn;0.35% accuracy<\/strong> and <strong>&plusmn;0.05% reproducibility<\/strong> across the entire flow range.<\/p><p>The target audience includes <strong>microfluidics researchers<\/strong>, <strong>pharmaceutical development teams<\/strong>, and any laboratory requiring ultra-precise fluid delivery. <strong>Drug delivery studies<\/strong>, <strong><a href=\"https:\/\/darwin-microfluidics.com\/categories\/microfluidic-organ-on-a-chip\/\"><b>organ-on-chip<\/b><\/a> research<\/strong>, and <strong>nanoparticle synthesis<\/strong> all benefit from this level of precision.<\/p><p>Key capabilities include advanced programming profiles for <strong>constant rate<\/strong>, <strong>ramp<\/strong>, <strong>gradient<\/strong>, and <strong>autofill<\/strong> operations. Users can create and store up to <strong>two custom methods<\/strong> with <strong>50 steps each<\/strong> directly on the pump. The <strong>RS-485 interface<\/strong> allows daisy-chaining up to <strong>99 pumps<\/strong> for complex multi-channel experiments.<\/p><p>The pump can be operated vertically to reduce bench footprint by <strong>55%<\/strong>, a practical consideration for crowded laboratory spaces. <strong>Advanced microstepping<\/strong> eliminates flow pulsation, critical for sensitive microfluidic applications.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a84ab4d elementor-widget elementor-widget-global elementor-global-34822 elementor-widget-pix-promo-box\" data-id=\"a84ab4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-lg position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/04\/11-Pico-plus-Elite-Programmable-Syringe-Pump-CTA.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-lg pix-opacity-8 pix-hover-opacity-10\" alt=\"Deliver ultra-low flow rates down to 0.54 pl\/min with 0.35% accuracy\"\/><a href=\"https:\/\/darwin-microfluidics.com\/products\/microfluidic-programmable-11-pico-plus-elite-syringe-pump-harvard-apparatus\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-white  \" style=\"font-size:12px; \"><span class=\"text-primary\" style=\"\">Precise Flow Control for Microfluidic Workflows<\/span><\/span><\/span><\/div><h5 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Deliver ultra-low flow rates down to 0.54 pl\/min with 0.35% accuracy<\/h5><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 \"><span>View Features<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04b71b2 elementor-widget elementor-widget-text-editor\" data-id=\"04b71b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Description of the dLSP 500 Digital Syringe Pump:<\/h2><p>The <a href=\"https:\/\/darwin-microfluidics.com\/products\/dlsp-500-digital-syringe-pump\"><b>dLSP 500 series<\/b><\/a> comes from a manufacturer focused on bringing <strong>modern digital connectivity<\/strong> to precision fluid handling. The product line includes <strong>four models<\/strong>: <strong>dLSP 510<\/strong> and <strong>520<\/strong> (standard), plus <strong>dLSP 510 Pro<\/strong> and <strong>520 Pro<\/strong> versions.<\/p><p>Standard models deliver <strong>&plusmn;0.5% linear travel accuracy<\/strong>, while <strong>Pro versions<\/strong> match the Harvard unit at <strong>&plusmn;0.35%<\/strong>. The Pro versions also achieve lower minimum flow rates of <strong>0.3 pL\/min<\/strong> compared to <strong>0.7 pL\/min<\/strong> on standard models. Maximum flow rates reach <strong>120 mL\/min<\/strong> with a <strong>60 mL syringe<\/strong> on single-channel units.<\/p><p>The <strong>dLSP 500<\/strong> targets laboratories that need <strong>flexible control options<\/strong> and <strong>regulatory compliance<\/strong>. The <strong>Pro version<\/strong> meets <strong>21CFR Part 11 requirements<\/strong>, making it suitable for pharmaceutical development and <strong>GLP\/GMP environments<\/strong> where electronic records and audit trails matter.<\/p><p><strong>Connectivity options<\/strong> set this pump apart. Beyond standard <strong>USB<\/strong> and <strong>RS-485<\/strong>, the <strong>dLSP 500<\/strong> includes <strong>Ethernet<\/strong>, <strong>Wi-Fi<\/strong>, and <strong>Bluetooth<\/strong>. Users can monitor and control the pump through a dedicated <strong>PC software package<\/strong> or <strong>Android app<\/strong>, enabling remote operation and integration with laboratory information management systems.<\/p><p>The <strong>7-inch IPS HD display<\/strong> provides a larger interface than competing units. <strong>Multi-step programming<\/strong> is available on Pro versions, with blocks for <strong>constant flow<\/strong>, <strong>ramp<\/strong>, <strong>loop<\/strong>, <strong>delay<\/strong>, <strong>repeat<\/strong>, and various <strong>trigger functions<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1cb04e1 elementor-widget elementor-widget-global elementor-global-34819 elementor-widget-pix-promo-box\" data-id=\"1cb04e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-lg position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/DLSP500-CTA.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-lg pix-opacity-8 pix-hover-opacity-10\" alt=\"Use the touchscreen, the Android app, or the software to manage complex workflows!\"\/><a href=\"https:\/\/darwin-microfluidics.com\/products\/microfluidic-programmable-11-pico-plus-elite-syringe-pump-harvard-apparatus\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-white  \" style=\"font-size:12px; \"><span class=\"text-primary\" style=\"\">Build Programmable Workflows for Demanding Lab Protocols<\/span><\/span><\/span><\/div><h5 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Use the touchscreen, the Android app, or the software to manage complex workflows!<\/h5><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 \"><span>View Features<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-542e9974 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"542e9974\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Feature-by-Feature Comparison<\/h2><h3>1- Flow Rate Range and Precision<\/h3><p>The <strong>Harvard Apparatus<\/strong> achieves a minimum flow rate of <strong>0.54 pL\/min<\/strong> across all configurations with consistent <strong>&plusmn;0.35% accuracy<\/strong>. The <strong>dLSP 500 Pro<\/strong> actually goes lower at <strong>0.3 pL\/min<\/strong>, but standard models only reach <strong>0.7 pL\/min<\/strong> with reduced <strong>&plusmn;0.5% accuracy<\/strong>.<\/p><p>For maximum flow rates, the <strong>dLSP 500<\/strong> dominates. Its single-channel configuration pushes <strong>120 mL\/min<\/strong> versus <strong>39.77 mL\/min<\/strong> from the Harvard unit. This matters for applications requiring rapid syringe refilling or higher-volume dispensing.<\/p><p><b><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f3c6.svg\" alt=\"&#127942;\"\/> Winner: Tie. Harvard wins on consistent precision across all models. dLSP 500 Pro wins on minimum flow rate. dLSP 500 wins on maximum throughput.<\/b><\/p><h3>2- User Interface and Display<\/h3><p>The <strong>dLSP 500<\/strong> features a <strong>7-inch IPS HD LCD display<\/strong> at <strong>1024&times;600 resolution<\/strong>. The Harvard unit uses a smaller <strong>4.3-inch WQVGA TFT touchscreen<\/strong>. Both offer intuitive icon-based interfaces for programming and monitoring.<\/p><p>The Harvard interface allows complete method creation without a PC. Users can build <strong>50-step programs<\/strong> directly on the touchscreen. The dLSP 500 requires PC software for multi-step programming on Pro versions, though basic operation works through the touchscreen.<\/p><p><strong>&nbsp;<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f3c6.svg\" alt=\"&#127942;\"\/> Winner: dLSP 500<\/strong> <b>for display size and clarity. Harvard wins for standalone programming capability.<\/b><\/p><h3>3- Connectivity Options<\/h3><p><strong>Harvard Apparatus<\/strong> provides <strong>USB Type B<\/strong>, <strong>RS-485<\/strong> for daisy-chaining, <strong>TTL I\/O<\/strong> through a 15-pin D-sub connector, and <strong>footswitch input<\/strong>. Up to <strong>99 pumps<\/strong> can be networked through RS-485.<\/p><p>The <strong>dLSP 500<\/strong> includes all wired options plus <strong>Ethernet<\/strong>, <strong>Wi-Fi<\/strong>, and <strong>Bluetooth<\/strong>. The <strong>Android app<\/strong> enables smartphone control. This wireless capability allows remote monitoring and integration with modern lab automation systems.<\/p><p><strong><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f3c6.svg\" alt=\"&#127942;\"\/> Winner: dLSP 500<\/strong> <b>by a significant margin for connectivity flexibility.<\/b><\/p><h3>4- Build Quality and Footprint<\/h3><p>The Harvard unit weighs <strong>2.1 kg<\/strong> with dimensions of <strong>22.6 x 17.78 x 15 cm<\/strong>. It can operate vertically to reduce bench footprint by <strong>55%<\/strong>. The tilting display accommodates vertical orientation.<\/p><p>The <strong>dLSP 500<\/strong> drive unit measures <strong>260 x 185 x 180 mm<\/strong> and weighs <strong>3.49 kg<\/strong>, plus a separate <strong>0.37 kg<\/strong> controller. The two-piece design offers flexibility but requires more total bench space.<\/p><p><strong>Winner: Harvard Apparatus<\/strong> for compact design and vertical operation capability.<\/p><h3>5- Regulatory Compliance<\/h3><p>The <strong>Harvard Apparatus<\/strong> carries <strong>CE<\/strong>, <strong>ETL (UL, CSA)<\/strong>, <strong>WEEE<\/strong>, <strong>EU RoHS<\/strong>, and <strong>CB Scheme<\/strong> certifications. These cover safety and environmental requirements but not pharmaceutical documentation standards.<\/p><p>The <strong>dLSP 500 Pro<\/strong> meets <strong>21CFR Part 11<\/strong> requirements for electronic records and signatures. This matters for pharmaceutical development, clinical research, and any <strong>GLP\/GMP environment<\/strong> requiring audit trails.<\/p><p><strong>&nbsp;<img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f3c6.svg\" alt=\"&#127942;\"\/>Winner: dLSP 500 Pro<\/strong> <b>for pharmaceutical and regulated environments.<\/b><\/p><h3>6- Linear Force<\/h3><p>The <strong>Harvard Apparatus<\/strong> delivers <strong>35 lbs (16 kg)<\/strong> of linear force at 100% selection. The <strong>dLSP 500<\/strong> provides <strong>40 lbs (18 kg)<\/strong> under the same conditions. Higher force helps when pushing viscous fluids or overcoming back pressure in microfluidic systems.<\/p><p><strong><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f3c6.svg\" alt=\"&#127942;\"\/> Winner: dLSP 500<\/strong> with <strong>14% more pushing force<\/strong>.<\/p><h2>Pricing: Harvard Apparatus 11 Pico Plus Elite Syringe Pump vs dLSP 500 Digital Syringe Pump<\/h2><p>The <strong>Harvard Apparatus 11 Pico Plus Elite<\/strong> ranges from <strong>$4,299.75 to $4,429.62<\/strong>, with pricing varying between single and dual-channel configurations. This represents consistent pricing with minimal variation between options.<\/p><p>The <strong>dLSP 500 series<\/strong> spans <strong>$3,409.73 to $5,014.27<\/strong>. The standard <strong>dLSP 510<\/strong> and <strong>520 models<\/strong> sit at the lower end, while <strong>Pro versions<\/strong> with enhanced accuracy and <strong>21CFR Part 11 compliance<\/strong> command premium pricing.<\/p><p>For budget-conscious academic labs, the standard <strong>dLSP 510<\/strong> offers the lowest entry point. If <strong>&plusmn;0.5% accuracy<\/strong> meets your needs and you do not require pharmaceutical compliance, this represents solid value.<\/p><p>Mid-range buyers face an interesting choice. The <strong>Harvard Apparatus dual-channel model<\/strong> costs roughly the same as a <strong>dLSP 520 Pro<\/strong> but offers different advantages. Harvard provides the <strong>2-year warranty<\/strong> and established brand reputation. The dLSP 520 Pro delivers <strong>regulatory compliance<\/strong> and <strong>wireless connectivity<\/strong>.<\/p><p>For pharmaceutical or GMP environments, the <strong>dLSP 520 Pro<\/strong> justifies its higher price through <strong>21CFR Part 11 compliance<\/strong>. Building equivalent documentation systems around the Harvard unit would require additional software and validation effort.<\/p><p>Total cost of ownership should factor in accessories. The Harvard unit includes <strong>pump and power supply<\/strong>. The dLSP 500 includes <strong>pump<\/strong>, <strong>touchscreen controller<\/strong>, <strong>connecting cable<\/strong>, and <strong>power supply<\/strong>. Both require syringes purchased separately.<\/p><h2>The Verdict: Harvard Apparatus 11 Pico Plus Elite Syringe Pump or dLSP 500 Digital Syringe Pump?<\/h2><p><strong>&#9989; Choose the Harvard Apparatus 11 Pico Plus Elite if you:<\/strong><\/p><ul><li><strong>Need consistent &plusmn;0.35% accuracy<\/strong> without paying for a &quot;Pro&quot; upgrade<\/li><li><strong>Plan to network multiple pumps<\/strong> (up to 99 units via RS-485)<\/li><li><strong>Value the 2-year warranty<\/strong> and Harvard Apparatus brand reliability<\/li><li><strong>Work in space-constrained environments<\/strong> where vertical operation helps<\/li><li><strong>Require standalone programming<\/strong> without PC dependency<\/li><li><strong>Prioritize proven technology<\/strong> from a 120-year-old manufacturer<\/li><\/ul><p><strong>&nbsp;&#9989; Choose the dLSP 500 Digital Syringe Pump if you:<\/strong><\/p><ul><li><strong>Need wireless control<\/strong> via Wi-Fi, Bluetooth, or Android app<\/li><li><strong>Work in pharmaceutical or GLP\/GMP environments<\/strong> requiring 21CFR Part 11 compliance<\/li><li><strong>Want the lowest possible entry price<\/strong> (standard dLSP 510)<\/li><li><strong>Need maximum flow rates<\/strong> above 40 mL\/min<\/li><li><strong>Prefer a larger 7-inch display<\/strong> interface<\/li><li><strong>Require Ethernet connectivity<\/strong> for lab automation integration<\/li><\/ul><p>The <strong>Harvard Apparatus<\/strong> represents the established choice for precision microfluidics. The <strong>dLSP 500<\/strong> represents the modern choice for connected, regulated laboratories. <strong>Neither pump is universally superior.<\/strong> Your specific application requirements should drive the decision.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac5674f elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"ac5674f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Need some help with your microfluidic project?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/contact-us\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Contact our experts!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Need some help with your microfluidic project?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>We can make microfluidics easy for you!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3a741cf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3a741cf\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8006c07\" data-id=\"8006c07\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-997ef40 elementor-widget elementor-widget-text-editor\" data-id=\"997ef40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Frequently Asked Questions<\/h2><h4><strong>Which pump offers better accuracy for microfluidic applications?<\/strong><\/h4><p>Both achieve <strong>&plusmn;0.35% accuracy<\/strong> and <strong>&plusmn;0.05% reproducibility<\/strong> when comparing the Harvard Apparatus to the <strong>dLSP 500 Pro<\/strong>. Standard <strong>dLSP 500<\/strong> models offer <strong>&plusmn;0.5% accuracy<\/strong>. For ultra-precise microfluidic work, either the Harvard unit or dLSP Pro version will perform equivalently.<\/p><h4><strong>Can I control these pumps remotely?<\/strong><\/h4><p>The <strong>dLSP 500<\/strong> offers <strong>Wi-Fi<\/strong>, <strong>Bluetooth<\/strong>, and <strong>Ethernet<\/strong> connectivity plus an <strong>Android app<\/strong> for remote control. The <strong>Harvard Apparatus<\/strong> requires wired <strong>USB<\/strong> or <strong>RS-485<\/strong> connections for external control, with no wireless options available.<\/p><h4><strong>Which pump supports larger syringe volumes?<\/strong><\/h4><p>The <strong>Harvard Apparatus<\/strong> single-channel version accepts syringes up to <strong>50\/60 mL<\/strong>. The <strong>dLSP 510<\/strong> and <strong>510 Pro<\/strong> handle syringes up to <strong>60 mL<\/strong>. Dual-channel versions on both platforms max out at <strong>10 mL (Harvard)<\/strong> or <strong>30 mL (dLSP 520)<\/strong>.<\/p><h4><strong>Do either of these pumps meet pharmaceutical regulatory requirements?<\/strong><\/h4><p>The <strong>dLSP 500 Pro<\/strong> versions meet <strong>21CFR Part 11<\/strong> requirements for electronic records and signatures. The <strong>Harvard Apparatus<\/strong> carries standard safety certifications (<strong>CE, ETL, RoHS<\/strong>) but does not include pharmaceutical documentation compliance features.<\/p><h4><strong>What maintenance do these pumps require?<\/strong><\/h4><p>Both pumps use <strong>precision lead screws<\/strong> and <strong>stepper motors<\/strong> requiring minimal maintenance. Keep the syringe clamp mechanisms clean and verify calibration periodically. Neither manufacturer specifies routine maintenance intervals, suggesting these are low-maintenance instruments under normal laboratory conditions.<\/p><h4><strong>Can I use glass and plastic syringes with both pumps?<\/strong><\/h4><p><strong>Yes.<\/strong> Both the <strong>Harvard Apparatus<\/strong> and <strong>dLSP 500<\/strong> accept standard glass and plastic syringes. Syringe compatibility ranges from <strong>0.5 &mu;L to 60 mL<\/strong> depending on the specific model and configuration.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>11 Pico Plus Elite vs dLSP 500 Digital Syringe Pump: Quick Verdict The Harvard Apparatus 11 Pico Plus Elite wins for researchers who need the absolute lowest flow rates with proven accuracy from an established manufacturer. Its 0.54 pL\/min minimum&hellip;<\/p>\n","protected":false},"author":3,"featured_media":34811,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[67,24],"tags":[],"class_list":["post-34803","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-comparisons","category-flow-control"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose - Darwin Microfluidics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose - Darwin Microfluidics\" \/>\n<meta property=\"og:description\" content=\"11 Pico Plus Elite vs dLSP 500 Digital Syringe Pump: Quick Verdict The Harvard Apparatus 11 Pico Plus Elite wins for researchers who need the absolute lowest flow rates with proven accuracy from an established manufacturer. Its 0.54 pL\/min minimum...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-31T15:55:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:35:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose\",\"datePublished\":\"2026-03-31T15:55:05+00:00\",\"dateModified\":\"2026-11-19T14:35:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/\"},\"wordCount\":1746,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg\",\"articleSection\":[\"Comparisons &amp; buying guides\",\"Flow control\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/\",\"name\":\"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg\",\"datePublished\":\"2026-03-31T15:55:05+00:00\",\"dateModified\":\"2026-11-19T14:35:34+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg\",\"width\":1600,\"height\":900,\"caption\":\"picture of the Harvard Apparatus 11 Pico Plus Elite Syringe Pump VS dLSP 500 Digital Syringe Pump article\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose - Darwin Microfluidics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/","og_locale":"en_US","og_type":"article","og_title":"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose - Darwin Microfluidics","og_description":"11 Pico Plus Elite vs dLSP 500 Digital Syringe Pump: Quick Verdict The Harvard Apparatus 11 Pico Plus Elite wins for researchers who need the absolute lowest flow rates with proven accuracy from an established manufacturer. Its 0.54 pL\/min minimum...","og_url":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/","og_site_name":"Darwin Microfluidics","article_published_time":"2026-03-31T15:55:05+00:00","article_modified_time":"2026-11-19T14:35:34+00:00","og_image":[{"width":1600,"height":900,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg","type":"image\/jpeg"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose","datePublished":"2026-03-31T15:55:05+00:00","dateModified":"2026-11-19T14:35:34+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/"},"wordCount":1746,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg","articleSection":["Comparisons &amp; buying guides","Flow control"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/","url":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/","name":"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose - Darwin Microfluidics","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg","datePublished":"2026-03-31T15:55:05+00:00","dateModified":"2026-11-19T14:35:34+00:00","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg","width":1600,"height":900,"caption":"picture of the Harvard Apparatus 11 Pico Plus Elite Syringe Pump VS dLSP 500 Digital Syringe Pump article"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/11-pico-plus-elite-vs-dlsp-500-which-dual-channel-syringe-pump-should-you-choose\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"11 Pico Plus Elite vs dLSP 500: Which Dual-Channel Syringe Pump Should You Choose"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2026\/03\/Harvard-Apparatus-11-Pico-Plus-Elite-Syringe-PumpdLSP-500-Digital-Syringe-Pump.jpg","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/34803","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=34803"}],"version-history":[{"count":40,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/34803\/revisions"}],"predecessor-version":[{"id":34886,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/34803\/revisions\/34886"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/34811"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=34803"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=34803"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=34803"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}